An ion-imprinted polymer for the selective extraction of mercury(II) ions in aqueous media
- Batlokwa, Bareki Shima, Chimuka, Luke, Tshentu, Zenixole R, Cukrowska, Ewa, Torto, Nelson
- Authors: Batlokwa, Bareki Shima , Chimuka, Luke , Tshentu, Zenixole R , Cukrowska, Ewa , Torto, Nelson
- Date: 2012
- Language: English
- Type: Article
- Identifier: vital:6566 , http://hdl.handle.net/10962/d1004125
- Description: A double-imprinted polymer exhibiting high sensitivity for mercury(II) in aqueous solution is presented. Polymer particles imprinted with mercury(II) were synthesised by copolymerising the functional and cross-linking monomers, N’–[3– (Trimethoxysilyl)–propyl]diethylenetriamine (TPET) and tetraethylorthosilicate (TEOS). A double-imprinting procedure employing hexadecyltrimethylammonium bromide (CTAB), as a second template to improve the efficiency of the polymer, was adopted. The imprinted polymer was characterised by FTIR, scanning electron microscopy (SEM) and the average size determined by screen analysis using standard test sieves. Relative selective coefficients (k`) of the imprinted polymer evaluated from selective binding studies between Hg2+ and Cu2+ or Hg2+ and Cd2+ were 10 588 and 3 147, respectively. These values indicated highly-favoured Hg2+ extractions over the 2 competing ions. The results of spiked and real water samples showed high extraction efficiencies of Hg2+ ions, (over 84%) as evaluated from the detected unextracted Hg2+ ions by ICP-OES. The method exhibited a dynamic response concentration range for Hg2+ between 0.01 and 20 μg/mℓ, with a detection limit (LOD, 3σ) of 0.000036 μg/mℓ (36 ng/ℓ) that meets the monitoring requirements for the USA EPA of 2 000 ng/ℓ for Hg2+ in drinking water. Generally, the data (n=10) had percentage relative standard deviations (%RSD) of less than 4%. Satisfactory results were also obtained when the prepared sorbent was applied for the pre-concentration of Hg2+ from an aqueous certified reference material. These findings indicate that the double-imprinted polymer has potential to be used as an efficient extraction material for the selective pre–concentration of mercury(II) ions in aqueous environments.
- Full Text:
- Date Issued: 2012
- Authors: Batlokwa, Bareki Shima , Chimuka, Luke , Tshentu, Zenixole R , Cukrowska, Ewa , Torto, Nelson
- Date: 2012
- Language: English
- Type: Article
- Identifier: vital:6566 , http://hdl.handle.net/10962/d1004125
- Description: A double-imprinted polymer exhibiting high sensitivity for mercury(II) in aqueous solution is presented. Polymer particles imprinted with mercury(II) were synthesised by copolymerising the functional and cross-linking monomers, N’–[3– (Trimethoxysilyl)–propyl]diethylenetriamine (TPET) and tetraethylorthosilicate (TEOS). A double-imprinting procedure employing hexadecyltrimethylammonium bromide (CTAB), as a second template to improve the efficiency of the polymer, was adopted. The imprinted polymer was characterised by FTIR, scanning electron microscopy (SEM) and the average size determined by screen analysis using standard test sieves. Relative selective coefficients (k`) of the imprinted polymer evaluated from selective binding studies between Hg2+ and Cu2+ or Hg2+ and Cd2+ were 10 588 and 3 147, respectively. These values indicated highly-favoured Hg2+ extractions over the 2 competing ions. The results of spiked and real water samples showed high extraction efficiencies of Hg2+ ions, (over 84%) as evaluated from the detected unextracted Hg2+ ions by ICP-OES. The method exhibited a dynamic response concentration range for Hg2+ between 0.01 and 20 μg/mℓ, with a detection limit (LOD, 3σ) of 0.000036 μg/mℓ (36 ng/ℓ) that meets the monitoring requirements for the USA EPA of 2 000 ng/ℓ for Hg2+ in drinking water. Generally, the data (n=10) had percentage relative standard deviations (%RSD) of less than 4%. Satisfactory results were also obtained when the prepared sorbent was applied for the pre-concentration of Hg2+ from an aqueous certified reference material. These findings indicate that the double-imprinted polymer has potential to be used as an efficient extraction material for the selective pre–concentration of mercury(II) ions in aqueous environments.
- Full Text:
- Date Issued: 2012
Development of molecularly imprinted polymer based solid phase extraction sorbents for the selective cleanup of food and pharmaceutical residue samples
- Authors: Batlokwa, Bareki Shima
- Date: 2012
- Subjects: Sorbents -- Research Nanofibers -- Research Aflatoxins -- Research Electrospinning -- Research Extraction (Chemistry) -- Research
- Language: English
- Type: Thesis , Doctoral , PhD
- Identifier: vital:4309 , http://hdl.handle.net/10962/d1004967
- Description: This thesis presents the development of chlorophyll, cholic acid, aflatoxin B1 molecularly imprinted polymer (MIP) particles and cholic acid MIP nanofibers for application as selective solid phase extraction (SPE) sorbents. The particles were prepared by bulk polymerization and the nanofibers by a novel approach combining molecular imprinting and electrospinning technology. The AFB1 MIP particles were compared with an aflatoxin specific immunoextraction sorbent in cleaning-up and pre-concentrating aflatoxins from nut extracts. They both recorded high extraction efficiencies (EEs) of > 97 % in selectively extracting the aflatoxins (AFB1, AFB2, AFG1 and AFG2). High reproducibility marked by the low %RSDs of < 1% and low LODs of ≤ 0.02 ng/g were calculated in all cases. The LODs were within the monitoring requirements of the European Commission. The results were validated with a peanut butter certified reference material. The chlorophyll MIP on the other hand selectively removed chlorophyll that would otherwise interfere during pesticide residue analysis (PRA) from > 0.6 to <0.09 Au in green plants extracts. The extracted chlorophyll was removed to far below the level of ≥ 0.399 Au that is usually associated with interference during PRA. Furthermore, the MIP demonstrated better selectivity by removing only chlorophyll (> 99%) in the presence of planar pesticides than the currently employed graphitized carbon black (GCB) that removed both the chlorophyll (> 88%) and planar pesticides (> 89%). For the interfering cholic acid during drug residue analysis, cholic acid MIP electrospun nanofibers demonstrated to be more sensitive and possessing higher loading capacity than the MIP particles. 100% cholic acid was removed by the nanofibers from standard solutions relative to 80% by the particles. This showed that the nanofibers have better performance than the micro particles and as such have potential to replace the particle based SPE sorbents that are currently in use. All the templates were optimally removed from the prepared MIPs by employing a novel pressurized hot water extraction template removal method that was used for the first time in this thesis. The method employed only water, an environmentally friendly solvent to remove templates to ≥ 99.6% with template residual bleeding of ≤ 0.02%.
- Full Text:
- Date Issued: 2012
- Authors: Batlokwa, Bareki Shima
- Date: 2012
- Subjects: Sorbents -- Research Nanofibers -- Research Aflatoxins -- Research Electrospinning -- Research Extraction (Chemistry) -- Research
- Language: English
- Type: Thesis , Doctoral , PhD
- Identifier: vital:4309 , http://hdl.handle.net/10962/d1004967
- Description: This thesis presents the development of chlorophyll, cholic acid, aflatoxin B1 molecularly imprinted polymer (MIP) particles and cholic acid MIP nanofibers for application as selective solid phase extraction (SPE) sorbents. The particles were prepared by bulk polymerization and the nanofibers by a novel approach combining molecular imprinting and electrospinning technology. The AFB1 MIP particles were compared with an aflatoxin specific immunoextraction sorbent in cleaning-up and pre-concentrating aflatoxins from nut extracts. They both recorded high extraction efficiencies (EEs) of > 97 % in selectively extracting the aflatoxins (AFB1, AFB2, AFG1 and AFG2). High reproducibility marked by the low %RSDs of < 1% and low LODs of ≤ 0.02 ng/g were calculated in all cases. The LODs were within the monitoring requirements of the European Commission. The results were validated with a peanut butter certified reference material. The chlorophyll MIP on the other hand selectively removed chlorophyll that would otherwise interfere during pesticide residue analysis (PRA) from > 0.6 to <0.09 Au in green plants extracts. The extracted chlorophyll was removed to far below the level of ≥ 0.399 Au that is usually associated with interference during PRA. Furthermore, the MIP demonstrated better selectivity by removing only chlorophyll (> 99%) in the presence of planar pesticides than the currently employed graphitized carbon black (GCB) that removed both the chlorophyll (> 88%) and planar pesticides (> 89%). For the interfering cholic acid during drug residue analysis, cholic acid MIP electrospun nanofibers demonstrated to be more sensitive and possessing higher loading capacity than the MIP particles. 100% cholic acid was removed by the nanofibers from standard solutions relative to 80% by the particles. This showed that the nanofibers have better performance than the micro particles and as such have potential to replace the particle based SPE sorbents that are currently in use. All the templates were optimally removed from the prepared MIPs by employing a novel pressurized hot water extraction template removal method that was used for the first time in this thesis. The method employed only water, an environmentally friendly solvent to remove templates to ≥ 99.6% with template residual bleeding of ≤ 0.02%.
- Full Text:
- Date Issued: 2012
- «
- ‹
- 1
- ›
- »