A novel biosensor for the detection and monitoring of -d-galactosidase of faecal origin in water
- Wutor, V C, Togo, C A, Limson, Janice L, Pletschke, Brett I
- Authors: Wutor, V C , Togo, C A , Limson, Janice L , Pletschke, Brett I
- Date: 2007
- Language: English
- Type: Article
- Identifier: vital:6468 , http://hdl.handle.net/10962/d1005797 , http://dx.doi.org/10.1016/j.enzmictec.2006.10.039
- Description: A voltammetric sensor prepared by the immobilization of metallophthalocyanine complexes onto a glassy carbon electrode has been developed for the detection of β-d-galactosidase (B-GAL) of faecal origin in water. Electrooxidation of chlorophenol red, a breakdown product of the chromogenic substrate chlorophenol red β-d-galactopyranoside, was used as a measure of β-d-galactosidase activity. At metallophthalocyanine modified electrodes, in particular copper(II) phthalocyanine, a decrease in electrode fouling was observed. The sensor was sensitive to fluctuations in pH, not significantly affected by temperature variations and could detect one colony forming unit/100 mL in 15 min. Loss of 40% sensitivity was observed over a period of 30 days. A strong correlation between sensor sensitivity and colony forming units was observed. The sensor is capable of detecting viable but nonculturable bacteria, overcoming this drawback of the use of culture media for detection of coliforms.
- Full Text:
- Date Issued: 2007
- Authors: Wutor, V C , Togo, C A , Limson, Janice L , Pletschke, Brett I
- Date: 2007
- Language: English
- Type: Article
- Identifier: vital:6468 , http://hdl.handle.net/10962/d1005797 , http://dx.doi.org/10.1016/j.enzmictec.2006.10.039
- Description: A voltammetric sensor prepared by the immobilization of metallophthalocyanine complexes onto a glassy carbon electrode has been developed for the detection of β-d-galactosidase (B-GAL) of faecal origin in water. Electrooxidation of chlorophenol red, a breakdown product of the chromogenic substrate chlorophenol red β-d-galactopyranoside, was used as a measure of β-d-galactosidase activity. At metallophthalocyanine modified electrodes, in particular copper(II) phthalocyanine, a decrease in electrode fouling was observed. The sensor was sensitive to fluctuations in pH, not significantly affected by temperature variations and could detect one colony forming unit/100 mL in 15 min. Loss of 40% sensitivity was observed over a period of 30 days. A strong correlation between sensor sensitivity and colony forming units was observed. The sensor is capable of detecting viable but nonculturable bacteria, overcoming this drawback of the use of culture media for detection of coliforms.
- Full Text:
- Date Issued: 2007
Critical assessment of the quartz crystal microbalance with dissipation as an analytical tool for biosensor development and fundamental studies
- Fogel, Ronen, Mashazi, Philani N, Nyokong, Tebello, Limson, Janice L
- Authors: Fogel, Ronen , Mashazi, Philani N , Nyokong, Tebello , Limson, Janice L
- Date: 2007
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/271204 , vital:54521 , xlink:href="https://doi.org/10.1016/j.bios.2007.03.012"
- Description: One of the challenges in electrochemical biosensor design is gaining a fundamental knowledge of the processes underlying immobilisation of the molecules onto the electrode surface. This is of particular importance in biocomposite sensors where concerns have arisen as to the nature of the interaction between the biological and synthetic molecules immobilised. We examined the use of the Quartz Crystal Microbalance with Dissipation (QCM-D) as a tool for fundamental analyses of a model sensor constructed by the immobilisation of cobalt(II) phthalocyanine (TCACoPc) and glucose oxidase (GOx) onto a gold-quartz electrode (electrode surface) for the enhanced detection of glucose. The model sensor was constructed in aqueous phase and covalently linked the gold surface to the TCACoPc, and the TCACoPc to the GOx, using the QCM-D. The aqueous metallophthalocyanine (MPc) formed a multi-layer over the surface of the electrode, which could be removed to leave a monolayer with a mass loading that compared favourably to the theoretical value expected. Analysis of frequency and dissipation plots indicated covalent attachment of glucose oxidase onto the metallophthalocyanine layer. The amount of GOx bound using the model system compared favourably to calculations derived from the maximal amperometric functioning of the electrochemical sensor (examined in previously-published literature, Mashazi, P.N., Ozoemena, K.I., Nyokong, T., 2006. Electrochim. Acta 52, 177–186), but not to theoretical values derived from dimensions of GOx as established by crystallography. The strength of the binding of the GOx film with the TCACoPc layer was tested by using 2% SDS as a denaturant/surfactant, and the GOx film was not found to be significantly affected by exposure to this. This paper thus showed that QCM-D can be used in order to model essential processes and interactions that dictate the functional parameters of a biosensor.
- Full Text:
- Date Issued: 2007
- Authors: Fogel, Ronen , Mashazi, Philani N , Nyokong, Tebello , Limson, Janice L
- Date: 2007
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/271204 , vital:54521 , xlink:href="https://doi.org/10.1016/j.bios.2007.03.012"
- Description: One of the challenges in electrochemical biosensor design is gaining a fundamental knowledge of the processes underlying immobilisation of the molecules onto the electrode surface. This is of particular importance in biocomposite sensors where concerns have arisen as to the nature of the interaction between the biological and synthetic molecules immobilised. We examined the use of the Quartz Crystal Microbalance with Dissipation (QCM-D) as a tool for fundamental analyses of a model sensor constructed by the immobilisation of cobalt(II) phthalocyanine (TCACoPc) and glucose oxidase (GOx) onto a gold-quartz electrode (electrode surface) for the enhanced detection of glucose. The model sensor was constructed in aqueous phase and covalently linked the gold surface to the TCACoPc, and the TCACoPc to the GOx, using the QCM-D. The aqueous metallophthalocyanine (MPc) formed a multi-layer over the surface of the electrode, which could be removed to leave a monolayer with a mass loading that compared favourably to the theoretical value expected. Analysis of frequency and dissipation plots indicated covalent attachment of glucose oxidase onto the metallophthalocyanine layer. The amount of GOx bound using the model system compared favourably to calculations derived from the maximal amperometric functioning of the electrochemical sensor (examined in previously-published literature, Mashazi, P.N., Ozoemena, K.I., Nyokong, T., 2006. Electrochim. Acta 52, 177–186), but not to theoretical values derived from dimensions of GOx as established by crystallography. The strength of the binding of the GOx film with the TCACoPc layer was tested by using 2% SDS as a denaturant/surfactant, and the GOx film was not found to be significantly affected by exposure to this. This paper thus showed that QCM-D can be used in order to model essential processes and interactions that dictate the functional parameters of a biosensor.
- Full Text:
- Date Issued: 2007
- «
- ‹
- 1
- ›
- »