Analysis of chromameter results obtained from corticosteroid-induced skin blanching assay: comparison of visual and chromameter data
- Schwarb, Fabian P, Smith, Eric W, Haigh, John M, Surber, Christian
- Authors: Schwarb, Fabian P , Smith, Eric W , Haigh, John M , Surber, Christian
- Date: 1999
- Language: English
- Type: text , Article
- Identifier: vital:6426 , http://hdl.handle.net/10962/d1006562
- Description: In a Guidance document, the American FDA recommends the use of a Minolta chromameter rather than the human eye for the quantitative assessment of the pharmacodynamic blanching response produced by topical application of corticosteroids. The purpose of this study was to compare the appropriateness of the human eye and two models of chromameter for the estimation of skin blanching, in terms of the quality of the data generated by each method. The corticosteroid-induced skin blanching from four different betamethasone 17-valerate cream formulations was compared in a typical human skin blanching trial. The optimized assay methodology routinely practised in our laboratories was utilized. The blanching responses were assessed visually by three trained, independent observers and recorded by two chromameters (Minolta model CR-200 and model CR-300). The topical availability of the four creams was determined using visual scoring and chromameter measurements. All data were manipulated in such a manner as to produce a blanching response versus time profile from which AUBC analysis could be performed. Good correlation was observed between the visual assessments made by three independent observers. In contrast, moderate correlation was determined between visual, CR-200 and CR-300 measurements. Surprisingly, no direct linear relationship between the AUBCs produced by the two chromameters was observed indicating that the quality of the data obtained from the two instruments may not be equal. This investigation also indicated that the use of the chromameter is not completely objective. Visual scoring and chromameter measurement produce data sets that differ in quality. Each procedure needs to be validated and investigators have to be trained for both visual assessment and the operation of the chromameter, particularly with regard to the manipulation of the measuring head of the instrument.
- Full Text:
- Date Issued: 1999
- Authors: Schwarb, Fabian P , Smith, Eric W , Haigh, John M , Surber, Christian
- Date: 1999
- Language: English
- Type: text , Article
- Identifier: vital:6426 , http://hdl.handle.net/10962/d1006562
- Description: In a Guidance document, the American FDA recommends the use of a Minolta chromameter rather than the human eye for the quantitative assessment of the pharmacodynamic blanching response produced by topical application of corticosteroids. The purpose of this study was to compare the appropriateness of the human eye and two models of chromameter for the estimation of skin blanching, in terms of the quality of the data generated by each method. The corticosteroid-induced skin blanching from four different betamethasone 17-valerate cream formulations was compared in a typical human skin blanching trial. The optimized assay methodology routinely practised in our laboratories was utilized. The blanching responses were assessed visually by three trained, independent observers and recorded by two chromameters (Minolta model CR-200 and model CR-300). The topical availability of the four creams was determined using visual scoring and chromameter measurements. All data were manipulated in such a manner as to produce a blanching response versus time profile from which AUBC analysis could be performed. Good correlation was observed between the visual assessments made by three independent observers. In contrast, moderate correlation was determined between visual, CR-200 and CR-300 measurements. Surprisingly, no direct linear relationship between the AUBCs produced by the two chromameters was observed indicating that the quality of the data obtained from the two instruments may not be equal. This investigation also indicated that the use of the chromameter is not completely objective. Visual scoring and chromameter measurement produce data sets that differ in quality. Each procedure needs to be validated and investigators have to be trained for both visual assessment and the operation of the chromameter, particularly with regard to the manipulation of the measuring head of the instrument.
- Full Text:
- Date Issued: 1999
Effect of concentration and degree of saturation of topical fluocinonide formulations on in vitro membrane transport and in vivo availability on human skin
- Schwarb, Fabian P, Imanidis, Georgios, Smith, Eric W, Haigh, John M, Surber, Christian
- Authors: Schwarb, Fabian P , Imanidis, Georgios , Smith, Eric W , Haigh, John M , Surber, Christian
- Date: 1999
- Language: English
- Type: text , Article
- Identifier: vital:6425 , http://hdl.handle.net/10962/d1006560
- Description: Purpose. The thermodynamic acitvity of drugs in topical vehicles is considered to significantly influence topical delivery. In vitro diffusion across a synthetic membrane was shown to be correlated to the degree of saturation of the drug in the applied vehicle and therefore offers a potential for increased topical drug delivery. Fluocinonide a topical corticosteroid, was chosen as a model compound to investigate in vitro and in vivo availability from formulations with different degrees of saturation. Methods. Sub-, as well as, supersaturated drug solutions were prepared using PVP as an antinucleant agent. In vitro membrane diffusion experiments across silicone membrane and in vivo pharmacodynamic activity assessments, using the human skin blanching assay, were carried out. Results. Over the concentration range studied, the in vitro membrane transport of fluocinonide was proportional to the degree of saturation of the respective formulations. The in vivo pharmacodynamic response in the human skin blanching assay was related to the concentration of the drug in the vehicle irrespective of the degree of saturation. Conclusions. From the membrane permeation experiment it can be concluded, that the drug flux might be increased supra-proportionally with increasing donor concentration, drug (super-)saturation (proportional), beyond what would be anticipated based on ideal donor concentration and partition coefficient considerations only. These findings could not be confirmed in the in vivo investigation, probably due to additional vehicle effects (e.g., enhancement, irritation, drug binding) which have to be expected and could have altered the integrity of the stratum corneum and therewith topical bioavailability of the drug.
- Full Text: false
- Date Issued: 1999
- Authors: Schwarb, Fabian P , Imanidis, Georgios , Smith, Eric W , Haigh, John M , Surber, Christian
- Date: 1999
- Language: English
- Type: text , Article
- Identifier: vital:6425 , http://hdl.handle.net/10962/d1006560
- Description: Purpose. The thermodynamic acitvity of drugs in topical vehicles is considered to significantly influence topical delivery. In vitro diffusion across a synthetic membrane was shown to be correlated to the degree of saturation of the drug in the applied vehicle and therefore offers a potential for increased topical drug delivery. Fluocinonide a topical corticosteroid, was chosen as a model compound to investigate in vitro and in vivo availability from formulations with different degrees of saturation. Methods. Sub-, as well as, supersaturated drug solutions were prepared using PVP as an antinucleant agent. In vitro membrane diffusion experiments across silicone membrane and in vivo pharmacodynamic activity assessments, using the human skin blanching assay, were carried out. Results. Over the concentration range studied, the in vitro membrane transport of fluocinonide was proportional to the degree of saturation of the respective formulations. The in vivo pharmacodynamic response in the human skin blanching assay was related to the concentration of the drug in the vehicle irrespective of the degree of saturation. Conclusions. From the membrane permeation experiment it can be concluded, that the drug flux might be increased supra-proportionally with increasing donor concentration, drug (super-)saturation (proportional), beyond what would be anticipated based on ideal donor concentration and partition coefficient considerations only. These findings could not be confirmed in the in vivo investigation, probably due to additional vehicle effects (e.g., enhancement, irritation, drug binding) which have to be expected and could have altered the integrity of the stratum corneum and therewith topical bioavailability of the drug.
- Full Text: false
- Date Issued: 1999
Bioequivalence testing of topical dermatological formulations, the gap between science and legislation
- Schwarb, Fabian P, Smith, Eric W, Haigh, John M, Surber, Christian
- Authors: Schwarb, Fabian P , Smith, Eric W , Haigh, John M , Surber, Christian
- Date: 1998
- Language: English
- Type: Conference paper
- Identifier: vital:6341 , http://hdl.handle.net/10962/d1006608
- Description: Bioavailability concerns for topical dermatological products are complex and it is especially difficult to determine the bioequivalence of similar topical formulations. Since only small amounts of drug dispersed in an appropriate vehicle are applied to the skin, the amount of drug that actually reaches the systemic circulation is often too small to be easily quantified. Additionally, it can be argued that the relevance of any serum/plasma concentration-time curve of a topical agent is questionable, since the curve reflects the amount of drug after the active moiety has left the site of action. For some topical drugs e.g., topical corticosteroids, it is possible to perform a pharmacodynamic bioassay to obtain acceptable bioequivalence data. In this case, the intensity of the side effect of blanching (vasoconstriction) in the skin caused by topical corticosteroids can be measured. The response is directly proportional to the clinical efficacy, and the skin blanching assay has proved to be a reliable procedure for the determination of topical corticosteroid bioavailability. Recently, we had sight of the results of a topical bioequivalence study, which was conducted for the registration of a new generic corticosteroid cream formulation. In this trial the new formulation was compared to two equivalent product from the local market and bioequivalence was demonstrated by the investigators for all three products. These results were examined with interest as the respective reference products have been used repeatedly as standard formulations in our laboratory. However, one of these reference formulations has consistently shown superior bioavailability in our trials, but was not demonstrated to be superior in the study results examined. In the present publication an overview of topical bioequivalence testing in general is given and the difficulties occurring in practice, for topical corticosteroid formulations in particular, are demonstrated.
- Full Text:
- Date Issued: 1998
- Authors: Schwarb, Fabian P , Smith, Eric W , Haigh, John M , Surber, Christian
- Date: 1998
- Language: English
- Type: Conference paper
- Identifier: vital:6341 , http://hdl.handle.net/10962/d1006608
- Description: Bioavailability concerns for topical dermatological products are complex and it is especially difficult to determine the bioequivalence of similar topical formulations. Since only small amounts of drug dispersed in an appropriate vehicle are applied to the skin, the amount of drug that actually reaches the systemic circulation is often too small to be easily quantified. Additionally, it can be argued that the relevance of any serum/plasma concentration-time curve of a topical agent is questionable, since the curve reflects the amount of drug after the active moiety has left the site of action. For some topical drugs e.g., topical corticosteroids, it is possible to perform a pharmacodynamic bioassay to obtain acceptable bioequivalence data. In this case, the intensity of the side effect of blanching (vasoconstriction) in the skin caused by topical corticosteroids can be measured. The response is directly proportional to the clinical efficacy, and the skin blanching assay has proved to be a reliable procedure for the determination of topical corticosteroid bioavailability. Recently, we had sight of the results of a topical bioequivalence study, which was conducted for the registration of a new generic corticosteroid cream formulation. In this trial the new formulation was compared to two equivalent product from the local market and bioequivalence was demonstrated by the investigators for all three products. These results were examined with interest as the respective reference products have been used repeatedly as standard formulations in our laboratory. However, one of these reference formulations has consistently shown superior bioavailability in our trials, but was not demonstrated to be superior in the study results examined. In the present publication an overview of topical bioequivalence testing in general is given and the difficulties occurring in practice, for topical corticosteroid formulations in particular, are demonstrated.
- Full Text:
- Date Issued: 1998
Chromametry: measuring precision of diurnal and local variation of human forearm skin colour
- Schwarb, Fabian P, Smith, Eric W, Haigh, John M, Surber, Christian
- Authors: Schwarb, Fabian P , Smith, Eric W , Haigh, John M , Surber, Christian
- Date: 1998
- Language: English
- Type: Conference paper
- Identifier: vital:6343 , http://hdl.handle.net/10962/d1006610
- Description: Chromameters are compact portable instruments used for the assessment of surface colour based on the tristimulus analysis of a reflected xenon light pulse, and have been used for the quantification of erythema in the study of irritant dermatitis, and corticosteroid-induced skin blanching in the vasoconstriction assay. The variability and the reproducibility of chromameter results were investigated since it is known that the location and application force of the measuring head on the skin and the orthostatic maneuver of the arms influence the colour measurement. Furthermore the diurnal variation and the homogeneity of forearm skin colour were investigated.
- Full Text:
- Date Issued: 1998
- Authors: Schwarb, Fabian P , Smith, Eric W , Haigh, John M , Surber, Christian
- Date: 1998
- Language: English
- Type: Conference paper
- Identifier: vital:6343 , http://hdl.handle.net/10962/d1006610
- Description: Chromameters are compact portable instruments used for the assessment of surface colour based on the tristimulus analysis of a reflected xenon light pulse, and have been used for the quantification of erythema in the study of irritant dermatitis, and corticosteroid-induced skin blanching in the vasoconstriction assay. The variability and the reproducibility of chromameter results were investigated since it is known that the location and application force of the measuring head on the skin and the orthostatic maneuver of the arms influence the colour measurement. Furthermore the diurnal variation and the homogeneity of forearm skin colour were investigated.
- Full Text:
- Date Issued: 1998
Comparison of visual CR-200 and CR-300 chromameter data obtained from the corticosteroid-induced skin-blanching assay
- Schwarb, Fabian P, Smith, Eric W, Haigh, John M, Surber, Christian
- Authors: Schwarb, Fabian P , Smith, Eric W , Haigh, John M , Surber, Christian
- Date: 1998
- Language: English
- Type: Conference paper , text
- Identifier: vital:6344 , http://hdl.handle.net/10962/d1006611
- Description: In a recent Guidance document the American FDA recommended the use of a chromameterrather thanthe human eye for the assessment of the pharmacodynamic blanching response produced after topical application of corticosteroids. The purpose of this study was to investigate the appropriateness of the human eye and two types of chromameter for the estimation of skin blanching.
- Full Text:
- Date Issued: 1998
- Authors: Schwarb, Fabian P , Smith, Eric W , Haigh, John M , Surber, Christian
- Date: 1998
- Language: English
- Type: Conference paper , text
- Identifier: vital:6344 , http://hdl.handle.net/10962/d1006611
- Description: In a recent Guidance document the American FDA recommended the use of a chromameterrather thanthe human eye for the assessment of the pharmacodynamic blanching response produced after topical application of corticosteroids. The purpose of this study was to investigate the appropriateness of the human eye and two types of chromameter for the estimation of skin blanching.
- Full Text:
- Date Issued: 1998
- «
- ‹
- 1
- ›
- »