Development, manufacture and assessment of Clobetasol 17-propionate cream formulations
- Fauzee, Ayeshah Fateemah Beebee
- Authors: Fauzee, Ayeshah Fateemah Beebee
- Date: 2011
- Subjects: Adrenocortical hormones , Adrenocortical hormones -- Physiological effect , Adrenocortical hormones -- Testing , Drugs -- Testing , Drugs -- Development , Dermatopharmacology
- Language: English
- Type: Thesis , Masters , MSc
- Identifier: vital:3856 , http://hdl.handle.net/10962/d1013324
- Description: Eczema or dermatitis is the most common dermatological condition accounting for one-third of all diagnoses in the total population surveyed in South Africa. The prevalence of seborrhoeic dermatitis, extreme photodermatitis and severe psoriasis has increased markedly over the last decade and this increase may be ascribed to the HIV epidemic, first diagnosed in South Africa in 1982. Potent innovator corticosteroids, such as clobetasol 17-propionate (CP) that are used to treat skin disorders, are expensive and there is therefore a need for the production of generic topical corticosteroid products. Formulation and manufacturing processes can be challenging aspects for formulation scientists to produce a robust product that will elicit an appropriate and desirable pharmacokinetic-pharmacodynamic profile. Laboratory scale CP creams were manufactured using different concentrations of Gelot® 64 and propylene glycol in order to establish a composition that would produce a formulation, with similar physical and chemical characteristics and in vitro release profile as an innovator product, Dermovate®. These formulations were assessed in terms of their viscosity, spreadability, pH, content uniformity and in vitro release characteristics using a Franz diffusion cell apparatus. A formulation containing 3% w/w Gelot® 64 and 46% v/v propylene glycol (CPLS-02) was found to exhibit similar viscosity and spreadability characteristics and released CP in a manner similar to Dermovate®. The mechanism of drug release was evaluated using mathematical models such as zero order, first order and Higuchi models. In addition, the in vitro release profiles were characterised by use of difference (f1) and similarity (f2 and Sd) factors. A scale-up formulation with the same % w/w composition as the laboratory scale was also investigated following manufacture using a Wintech® cream/ointment mixer. A Central Composite Design approach was used to investigate the effect of process variables on the performance of the scale-up cream formulations. The homogenisation speed, anchor speed, homogenisation time and cooling time were the process variables investigated. Thirty scale-up batches were manufactured and analysed in terms of their viscosity, spreadability, pH, % drug content and cumulative % drug released per unit area over 72 hours. Model fitting using Design-Expert® software was undertaken and revealed that a correlation between the process variables and the cream responses was most suitably described by quadratic polynomial relationships. The homogenisation speed had the most significant effect on the quality of the scale-up formulations, whereas the anchor speed had a secondary effect on the measured responses, for the formulations investigated. The qualitative interpretation and statistical analysis of the in vitro release data from the scale-up formulations using ANOVA and the f1, f2 and Sd factors revealed that one scale-up batch (CPSU-04), for which the process variables were a homogenisation speed of 1900 rpm, an anchor speed of 35 rpm, a homogenisation time of 100 minutes and a cooling time of 100 minutes, released CP at a similar rate and extent to Dermovate®. A diffusion-controlled mechanism appeared to be predominant in these formulations. A human skin blanching study, using both visual and chromameter assessments, was performed to establish whether batch CPSU-04 was bioequivalent to Dermovate®. The bioequivalence of the selected scale-up formulation to Dermovate® was confirmed, following the calculation of a 90% CI.
- Full Text:
- Date Issued: 2011
- Authors: Fauzee, Ayeshah Fateemah Beebee
- Date: 2011
- Subjects: Adrenocortical hormones , Adrenocortical hormones -- Physiological effect , Adrenocortical hormones -- Testing , Drugs -- Testing , Drugs -- Development , Dermatopharmacology
- Language: English
- Type: Thesis , Masters , MSc
- Identifier: vital:3856 , http://hdl.handle.net/10962/d1013324
- Description: Eczema or dermatitis is the most common dermatological condition accounting for one-third of all diagnoses in the total population surveyed in South Africa. The prevalence of seborrhoeic dermatitis, extreme photodermatitis and severe psoriasis has increased markedly over the last decade and this increase may be ascribed to the HIV epidemic, first diagnosed in South Africa in 1982. Potent innovator corticosteroids, such as clobetasol 17-propionate (CP) that are used to treat skin disorders, are expensive and there is therefore a need for the production of generic topical corticosteroid products. Formulation and manufacturing processes can be challenging aspects for formulation scientists to produce a robust product that will elicit an appropriate and desirable pharmacokinetic-pharmacodynamic profile. Laboratory scale CP creams were manufactured using different concentrations of Gelot® 64 and propylene glycol in order to establish a composition that would produce a formulation, with similar physical and chemical characteristics and in vitro release profile as an innovator product, Dermovate®. These formulations were assessed in terms of their viscosity, spreadability, pH, content uniformity and in vitro release characteristics using a Franz diffusion cell apparatus. A formulation containing 3% w/w Gelot® 64 and 46% v/v propylene glycol (CPLS-02) was found to exhibit similar viscosity and spreadability characteristics and released CP in a manner similar to Dermovate®. The mechanism of drug release was evaluated using mathematical models such as zero order, first order and Higuchi models. In addition, the in vitro release profiles were characterised by use of difference (f1) and similarity (f2 and Sd) factors. A scale-up formulation with the same % w/w composition as the laboratory scale was also investigated following manufacture using a Wintech® cream/ointment mixer. A Central Composite Design approach was used to investigate the effect of process variables on the performance of the scale-up cream formulations. The homogenisation speed, anchor speed, homogenisation time and cooling time were the process variables investigated. Thirty scale-up batches were manufactured and analysed in terms of their viscosity, spreadability, pH, % drug content and cumulative % drug released per unit area over 72 hours. Model fitting using Design-Expert® software was undertaken and revealed that a correlation between the process variables and the cream responses was most suitably described by quadratic polynomial relationships. The homogenisation speed had the most significant effect on the quality of the scale-up formulations, whereas the anchor speed had a secondary effect on the measured responses, for the formulations investigated. The qualitative interpretation and statistical analysis of the in vitro release data from the scale-up formulations using ANOVA and the f1, f2 and Sd factors revealed that one scale-up batch (CPSU-04), for which the process variables were a homogenisation speed of 1900 rpm, an anchor speed of 35 rpm, a homogenisation time of 100 minutes and a cooling time of 100 minutes, released CP at a similar rate and extent to Dermovate®. A diffusion-controlled mechanism appeared to be predominant in these formulations. A human skin blanching study, using both visual and chromameter assessments, was performed to establish whether batch CPSU-04 was bioequivalent to Dermovate®. The bioequivalence of the selected scale-up formulation to Dermovate® was confirmed, following the calculation of a 90% CI.
- Full Text:
- Date Issued: 2011
Development and in vitro evaluation of a clobetasol 17-propionate topical cream formulation
- Authors: Wa Kasongo, Kasongo
- Date: 2007
- Subjects: Adrenocortical hormones , Adrenocortical hormones -- Physiological effect , Drugs -- Testing , Drug development , Dermatopharmacology
- Language: English
- Type: Thesis , Masters , MPharm
- Identifier: vital:3799 , http://hdl.handle.net/10962/d1003277 , Adrenocortical hormones , Adrenocortical hormones -- Physiological effect , Drugs -- Testing , Drug development , Dermatopharmacology
- Description: One of the primary contributing factors to the escalating costs of health care is the high cost of innovator pharmaceutical products. As a consequence, health authorities in various countries and in particular in the developing world have identified generic prescribing and generic substitution as possible strategies to contain the escalating costs of health care provision. There is therefore a need for formulation scientists in developing countries to invest more time in the research and development of generic formulations. Clobetasol 17-propionate (CP) generic cream formulations containing 0.05% w/w of the drug were manufactured and characterized using in vitro testing. Formulation development studies were preceded by the development and validation of an RP-HPLC with UV detection for the quantitation and characterization of CP in innovator and generic cream formulations during formulation development and assessment studies. Furthermore the in vitro release ates of CP release from innovator and generic cream formulations were monitored using a validated in vitro release test method developed in these studies. The formulation of CP cream products was accomplished using a variety of commercially available mixed primary emulsifiers, such as Estol® 1474, Ritapro® 200, Emulcire® 61 WL and Gelot® 64. Successful formulations were selected based on their ability to remain physically stable immediately after manufacture and for 24 hours after storage at room temperature (22°C). Estol® 1474 was found to produce an unstable cream and was therefore not investigated further. The other three emulgents produced stable creams, but only the in vitro release profile of CP from a cream manufactured to contain Gelot® 64 was found to be statistically similar to that of the innovator formulation. Therefore the cream containing Gelot® 64 was selected as the most appropriate prototype generic cream formulation and was characterized in vitro in terms of CP content, viscosity, pH and in vitro release rate. Data generated from these studies were compared to those of the innovator product, Dermovate® cream, using statistical methods. The CP content, pH and in vitro release rate data of the CP formulation were similar to those of the innovator product, however the intrinsic viscosity of Dermovate® cream was almost three (3) times greater than the intrinsic viscosity of the test formulation developed using Gelot® 64. The CP cream formulation developed in these studies was stored for 4 weeks at 40 ± 2°C and 25 ± 5% RH in an incubator and the formulation was found to be stable. A formulation has been developed and assessed and found to be suitable for use as a topical semi-solid dosage form for CP.
- Full Text:
- Date Issued: 2007
- Authors: Wa Kasongo, Kasongo
- Date: 2007
- Subjects: Adrenocortical hormones , Adrenocortical hormones -- Physiological effect , Drugs -- Testing , Drug development , Dermatopharmacology
- Language: English
- Type: Thesis , Masters , MPharm
- Identifier: vital:3799 , http://hdl.handle.net/10962/d1003277 , Adrenocortical hormones , Adrenocortical hormones -- Physiological effect , Drugs -- Testing , Drug development , Dermatopharmacology
- Description: One of the primary contributing factors to the escalating costs of health care is the high cost of innovator pharmaceutical products. As a consequence, health authorities in various countries and in particular in the developing world have identified generic prescribing and generic substitution as possible strategies to contain the escalating costs of health care provision. There is therefore a need for formulation scientists in developing countries to invest more time in the research and development of generic formulations. Clobetasol 17-propionate (CP) generic cream formulations containing 0.05% w/w of the drug were manufactured and characterized using in vitro testing. Formulation development studies were preceded by the development and validation of an RP-HPLC with UV detection for the quantitation and characterization of CP in innovator and generic cream formulations during formulation development and assessment studies. Furthermore the in vitro release ates of CP release from innovator and generic cream formulations were monitored using a validated in vitro release test method developed in these studies. The formulation of CP cream products was accomplished using a variety of commercially available mixed primary emulsifiers, such as Estol® 1474, Ritapro® 200, Emulcire® 61 WL and Gelot® 64. Successful formulations were selected based on their ability to remain physically stable immediately after manufacture and for 24 hours after storage at room temperature (22°C). Estol® 1474 was found to produce an unstable cream and was therefore not investigated further. The other three emulgents produced stable creams, but only the in vitro release profile of CP from a cream manufactured to contain Gelot® 64 was found to be statistically similar to that of the innovator formulation. Therefore the cream containing Gelot® 64 was selected as the most appropriate prototype generic cream formulation and was characterized in vitro in terms of CP content, viscosity, pH and in vitro release rate. Data generated from these studies were compared to those of the innovator product, Dermovate® cream, using statistical methods. The CP content, pH and in vitro release rate data of the CP formulation were similar to those of the innovator product, however the intrinsic viscosity of Dermovate® cream was almost three (3) times greater than the intrinsic viscosity of the test formulation developed using Gelot® 64. The CP cream formulation developed in these studies was stored for 4 weeks at 40 ± 2°C and 25 ± 5% RH in an incubator and the formulation was found to be stable. A formulation has been developed and assessed and found to be suitable for use as a topical semi-solid dosage form for CP.
- Full Text:
- Date Issued: 2007
Evaluation of the safety and efficacy of topical mometasone furoate formulations
- Authors: Chamboko, Bernadett Vongayi
- Date: 2007
- Subjects: Adrenocortical hormones -- Physiological effect , Drugs -- Testing , Dermatopharmacology , High performance liquid chromatography
- Language: English
- Type: Thesis , Masters , MSc
- Identifier: vital:3748 , http://hdl.handle.net/10962/d1003226 , Adrenocortical hormones -- Physiological effect , Drugs -- Testing , Dermatopharmacology , High performance liquid chromatography
- Description: The human skin blanching assay (HSBA) is a well-researched and validated method for the bioequivalence assessment of topical corticosteroids. Traditionally, visual assessment of skin blanching has been used. Such testing methods are not conducive for interlaboratory comparisons. Regulatory bodies prefer less subjective methods of analysis. The FDA released guidelines on the assessment of bioequivalence for topical corticosteroids that recommends the use of a chromameter as a reliable method to measure skin blanching although the use of visual assessment with acceptable validation is also provided for. However, the FDA does not elucidate on the manipulation and handling of the chromameter during skin blanching measurements. The purpose of this project was several fold, which included investigations to standardize the manipulation and handling of a chromameter. In particular, measures to avoid skin whitening resulting from the effects of pressure on the skin during chromameter use were investigated. Other methods of analysis should surpass or at least be comparable to the HSBA if such methods are to be used for the assessment of topical corticosteroids. Microdialysis is a relatively new technique for assessing the rate at which drug penetrates the skin. The advantage of using this method is that there are fewer restrictions for selection of an appropriate study population unlike those required for the HSBA where one has to be both a ‘responder’ and a ‘detector’ for their results to be used in data analysis. Microdialysis was investigated by initially conducting experiments in which microdialysis probes were embedded into topical formulations containing mometasone furoate (MF) and the initial results revealed that relatively low drug was released from the formulations. These results indicated that should microdialysis be applied to measure the in vivo release of MF from such topical formulations following application to the skin, even lower concentrations of MF would likely result in the dialysate, necessitating the need for ultra-high sensitive methods of analysis. Typically, the availability of an appropriate analytical technique such as liquid chromatography coupled with mass spectrometry (LCMS) would be a pre-requisite for such in vivo studies. However, only high-pressure liquid chromatography (HPLC) and other less sensitive equipment was available in the laboratories. The study objectives were therefore focussed on in vitro assessment of the release of MF from topical formulations using microdialysis and Franz cells. In addition, the in vivo release of MF was also studied using the HSBA. Data obtained from the microdialysis experiments were compared with the data obtained from the Franz cell diffusion studies in order to provide information on the pharmaceutical availability of MF from the various topical MF dosage forms. Subsequently, pharmaceutical equivalence was investigated from the comparative pharmaceutical availability data using statistical analysis. An additional objective was to attempt to correlate in vitro with in vivo data (IVIVC) to establish a model that could be used to assess safety and efficacy of generic topical drug products. The in vivo data obtained from the HSBA were processed according to the FDA requirements and these pharmacodynamic data were subsequently compared with the microdialysis and Franz cell results. In summary the objectives of this project were: 1. To develop a system to improve the reproducibility of the use of a Minolta® chromameter and compare this with the standard/normal manipulation and handling of such instruments. 2. To develop and validate an HPLC method for the analysis of MF for use with in vitro diffusion studies using microdialysis and Franz cells. 3. To conduct a comparative HSBA on proprietary MF topical creams from two different countries in accordance with the FDA guidance. 4. To assess the pharmaceutical equivalence of topical formulations containing MF using Franz diffusion cells and in vitro microdialysis. 5. To compare the in vivo data obtained from the HSBA with those obtained in vitro using microdialysis and Franz cells.
- Full Text:
- Date Issued: 2007
- Authors: Chamboko, Bernadett Vongayi
- Date: 2007
- Subjects: Adrenocortical hormones -- Physiological effect , Drugs -- Testing , Dermatopharmacology , High performance liquid chromatography
- Language: English
- Type: Thesis , Masters , MSc
- Identifier: vital:3748 , http://hdl.handle.net/10962/d1003226 , Adrenocortical hormones -- Physiological effect , Drugs -- Testing , Dermatopharmacology , High performance liquid chromatography
- Description: The human skin blanching assay (HSBA) is a well-researched and validated method for the bioequivalence assessment of topical corticosteroids. Traditionally, visual assessment of skin blanching has been used. Such testing methods are not conducive for interlaboratory comparisons. Regulatory bodies prefer less subjective methods of analysis. The FDA released guidelines on the assessment of bioequivalence for topical corticosteroids that recommends the use of a chromameter as a reliable method to measure skin blanching although the use of visual assessment with acceptable validation is also provided for. However, the FDA does not elucidate on the manipulation and handling of the chromameter during skin blanching measurements. The purpose of this project was several fold, which included investigations to standardize the manipulation and handling of a chromameter. In particular, measures to avoid skin whitening resulting from the effects of pressure on the skin during chromameter use were investigated. Other methods of analysis should surpass or at least be comparable to the HSBA if such methods are to be used for the assessment of topical corticosteroids. Microdialysis is a relatively new technique for assessing the rate at which drug penetrates the skin. The advantage of using this method is that there are fewer restrictions for selection of an appropriate study population unlike those required for the HSBA where one has to be both a ‘responder’ and a ‘detector’ for their results to be used in data analysis. Microdialysis was investigated by initially conducting experiments in which microdialysis probes were embedded into topical formulations containing mometasone furoate (MF) and the initial results revealed that relatively low drug was released from the formulations. These results indicated that should microdialysis be applied to measure the in vivo release of MF from such topical formulations following application to the skin, even lower concentrations of MF would likely result in the dialysate, necessitating the need for ultra-high sensitive methods of analysis. Typically, the availability of an appropriate analytical technique such as liquid chromatography coupled with mass spectrometry (LCMS) would be a pre-requisite for such in vivo studies. However, only high-pressure liquid chromatography (HPLC) and other less sensitive equipment was available in the laboratories. The study objectives were therefore focussed on in vitro assessment of the release of MF from topical formulations using microdialysis and Franz cells. In addition, the in vivo release of MF was also studied using the HSBA. Data obtained from the microdialysis experiments were compared with the data obtained from the Franz cell diffusion studies in order to provide information on the pharmaceutical availability of MF from the various topical MF dosage forms. Subsequently, pharmaceutical equivalence was investigated from the comparative pharmaceutical availability data using statistical analysis. An additional objective was to attempt to correlate in vitro with in vivo data (IVIVC) to establish a model that could be used to assess safety and efficacy of generic topical drug products. The in vivo data obtained from the HSBA were processed according to the FDA requirements and these pharmacodynamic data were subsequently compared with the microdialysis and Franz cell results. In summary the objectives of this project were: 1. To develop a system to improve the reproducibility of the use of a Minolta® chromameter and compare this with the standard/normal manipulation and handling of such instruments. 2. To develop and validate an HPLC method for the analysis of MF for use with in vitro diffusion studies using microdialysis and Franz cells. 3. To conduct a comparative HSBA on proprietary MF topical creams from two different countries in accordance with the FDA guidance. 4. To assess the pharmaceutical equivalence of topical formulations containing MF using Franz diffusion cells and in vitro microdialysis. 5. To compare the in vivo data obtained from the HSBA with those obtained in vitro using microdialysis and Franz cells.
- Full Text:
- Date Issued: 2007
- «
- ‹
- 1
- ›
- »